Introduction to the probe
- 3.5MHzR65 multi-frequency convex probe
- 6.5MHzR10 multi-frequency convex probe
- 7.5MHzL46 multi-frequency linear probe
- 3.0MHzL19 multi-frequency phased-array probe
- 4.0MHzR40 multi-frequency convex volume probe
3.5MHzR65 multi-frequency convex probe
The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode, they have a scanning angle of 60°. In the M-Mode, they can activate a particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: examination and diagnosis of abdominal tissues, such as liver, gallbladder, spleen, pancreas, kidneys, gastro-intestinal, uterus, urinary bladder, prostate, etc.; assessment of growth and maturity of the fetus in obstetric diagnosis.
6.5MHzR10 multi-frequency convex probe
The probes have a frequency range between 5.0MHz-9.0MHz. In the B-Mode, they have a scanning angle of 140-158°. In the M-Mode, they can activate a particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: vagina, uterus, rectum, rectum wall, prostate, etc.
Warning: Oil- and bacteria-free rubber sleeves must be added when using the probes. The probes should not be activated until going into the patient’s body.
7.5MHzL46 multi-frequency linear probe
The probes have a frequency range between 6.0MHz-12.0MHz. In the B-Mode, they have a scanning width of 38-45. In the M-Mode, they can activate a particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: newborns, musculoskeletal system, peripheral vessels, small parts (including breasts, thyroid, testis, etc.)
3.0MHzL19 multi-frequency phased-array probe
The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode, they have a scanning angle of 90°. In the M-Mode, they can activate a particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: heart, abdominal tissues, and parts
4.0MHzR40 multi-frequency convex volume probe
The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode, they have a scanning angle of 70°. In the M-Mode, they can activate a particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.
Scope of application: real-time 3D scan; examination and diagnosis of the fetus, abdominal tissues, uterus, etc.; assessment of growth and maturity of the fetus in obstetric diagnosis.